Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5111 VIBRATION (Cathode-ray tubes) Vibration (cathode-ray tubes). Each tube shall be vibrated along X and Y axes and shall withstand, without damage, simple harmonic vibration, at an amplitude of .040 ± .0025 inch (0.10 ± 0.063 mm), (.080 ± .005 inch (2.03 ± 0.13 mm) total excursion), at a frequency of 25 ± 2 Hz for 60 seconds and at a frequency of 50 ± 2 Hz for 300 seconds, in each direction. The increase in line width or displacement of the spot or trace due to the relative motion of the tube parts shall not exceed the limit(s) specified.
Electrostatic-deflection tubes shall be vibrated with a circular trace adjusted for optimum focus. Magnetic deflection, electrostatic- focus tubes, shall be vibrated with a low-intensity optimum-focus spot. Magnetic deflection, magnetic-focus tubes, shall be vibrated with a low-intensity spot corresponding to the image of the final aperture. METHOD 5111 5111-1 19 April 1968