Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5206 GAS (Cathode-ray tubes) 1. Gas "cross" (electrostatic deflection). Test voltage, as specified, shall be applied and the trace adjusted to focus. The screen of the tube shall be scanned to yield a square pattern having an area equal to approximately 2 by 2 inches (50.8 mm by 50.8 mm). Linear saw-tooth scanning as follows shall be used: Horizontal - - - - - - - - - - - - 2,100 to 6,300 Hz Vertical - - - - - - - - - - - - - - 60 Hz When the light output or screen current is set at the value specified on the TSS, the appearance on the screen of a "cross" is indicative of excessive gas.

All tubes upon which crosses appear shall be rejected. 2. Gas ratio (magnetic deflection). With voltage as specified in conditions A and B and with focus, scanners, and ion trap magnets off, Ik (mA dc) and Ib ( µ A dc) shall be determined. Condition A Condition B Eb = -25 V Ec2 = +300 V Ec1/Ik = 500 µ A dc Eb = -25 V Ec2 = +300 V Ec1 = -90 V For types with cutoff voltage greater than 90, use sufficient bias to insure cutoff. The value of gas ratio (Gr) shall be computed from the following equation and shall not exceed the limits specified on the TSS. 500 .0 ) ( ) ( B condition Ib A condition Ib Gr = METHOD 5206 5206-1 19 April 1968