Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D SPURIOUS ILLUMINATION METHOD 5216 (Cathode-ray tubes) 1. Cathode illumination. This test should normally be performed during qualification inspection only. With the tube enclosed in a lightproof container and with the specified heater potential applied for a minimum of 60 seconds, the light output at the face of the tube shall be not more than 0.154 mfL in any 2-inch (50.8 mm) diameter area. 2. Stray light emission (conventional types). There shall be no visible stray emission when viewed at a distance of 2 or 3 times the screen height and with 0.4 foot candle (ftC) diffused ambient illumination measured at the tube face. 3.

Effects of grid emission. The following test is applicable only to tube types used in low-ambient light conditions. Each gun shall be operated for a minimum of 5 minutes with maximum potentials applied to heater and accelerating anodes. Ec1 shall be maximum negative; positioning and deflection voltages shall be zero. Viewed under dark conditions with the eye dark-adapted for 5 minutes, there shall be no visible evidence of fluorescent light when Eb1 is varied from minimum to maximum. METHOD 5216 5216-1 19 April 1968