Downloaded from https://www.everyspec.com MIL-STD-1311D SCREEN INTENSITY AND PERSISTENCE METHOD 5221 (Cathode-ray tubes) 1. Light output. The light output of the screen shall be measured under the specified conditions and the following general conditions: A 35- to 105-line pattern shall be provided on the cathode-ray tube screen, using a 60 Hz saw-tooth scanning on one axis and a 2,100 to 6,300 Hz saw-tooth scanning on the other axis. In the case of electrostatic deflection types, the mean potential of free deflecting plates shall be that of anode No. 2. The pattern size shall be adjusted to 2 by 2 inches (50.8 mm by 50.8 mm), and the light output shall be read.
A foot-candle (ftC) meter or foot lambert (fL) meter, corrected for the spectral response of the eye, shall be used to measure the light output. The light output so determined shall be not less than the value specified on the TSS. When these conditions are satisfied, and the light meter is placed so that the sensitized surface of the photocell is against the tube face, the meter may be used to read fL directly. 2. Screens. The phosphorescent light intensity "D" observed "t" seconds after completion of the application of the "Nth" raster to the tube is Dt(N), for example, D1(5) is the phosphorescent light intensity 1 second after the fifth excitation raster.
Dt(E) shall denote that raster's are applied until equilibrium is reached. The cbf shall be fluorescent light output under continuous raster excitation. Buildup factor is described as G5:1 and is defined as the ratio of the light intensity obtained 1 second after the fifth raster to the light intensity obtained 1 second after the first raster. Unless otherwise specified, the screen characteristics shall be measured under the following conditions: a. Raster size (focused beam). Where tube size or useful scan permits 7.1 cm by 7.1 cm giving a total area of 50 cm 2 . Smaller tubes.
4.1 cm by 4.1 cm giving a total area of 16.7 cm 2 (48 cB shall be added to cB readings to correct for smaller raster size). The tube shall then be defocused to a spot approximately 0.25 cm in diameter. b. Beam current. Tubes shall be operated at a current to produce the power shown below when operated at the specified test voltage: Power in watts for raster size Screen 16.7 sq. cm. P2 P7 P12 P14 P19 P25 50 sq. cm. 0.24 0.24 0.02 0.24 0.02 0.05 0.08 0.08 0.007 0.08 0.007 0.017 c. Duration of raster = 0.0167 second. The raster is formed by means of linear scanning with the horizontal scanning frequency 12 kHz and the vertical scanning frequency 60 Hz.
The raster is repeated at 1-second intervals. d. Distance of raster from axis of calibrated 931 VA multiplier phototube = 30 cm. e. Red or white light. Sufficient to de-excite the phosphor before buildup measurements so that the results are within 3 cB of those that would have been obtained after total de-excitation. 3. Deviations from the conditions listed above in regard to test voltages, currents, and pattern size, required to test a number of different tube types will be permissible if such deviations are approved by the service concerned. NOTE:
Descriptions of primary standard replica lamps for various screen types are specified in Naval Material Laboratory Final Report Number 5032-B15.40. Data on phosphors P19 and P25 are included in Naval Material Laboratory Final Report Number 5032-B15.91. These reports may be obtained in accordance with section 2.1 of this standard. METHOD 5221 5221-1 19 April 1968