Downloaded from https://www.everyspec.com MIL-STD-1311D 4. Centibels (CB) may be converted to millifoot-Lamberts (mfL) by use of the following equations: Screen type Conversion equation 1/ P2 mfL = 2.70 x 10 -3 x 1K P7 with Wratten 15 filter, or equivalent mfL = 2.45 x 10 -3 x 1K P12 mfL = 1.82 x 10 -3 x 1K P14 with Wratten 15 filter, or equivalent mfL = 3.09 x 10 -3 x 1K P19 mfL = 1.77 x 10 -3 x 1K P25 mfL = 3.88 x 10 -3 x 1K 1/ K = 10 raised to the 100 cB power. 4.1 Using the symbols defined above, the light output measurements presently specified for the various types of phosphors are as follows:
D1(1) D1(5), G5:1 cBf, DO.1(E)-DO.3(E) D1(E), cBf, DO.1(E)-D1(E), D1(E)-D10(E) cBf, DO.1(10), D1(10), D1(10)-D10(10) cBf, DO.1(10), D1(10), D1(10)-D10(10) 4.2 The values for the measurements are as follows:
P2 P7 P12 P14 P19 P25 P2 D1(1) = 360 cB (minimum) P7 D1(5) = 400 cB (minimum) G5:1 = 4 P12 cBf = 550 cB (minimum) DO.1(E) - DO.3(E) = 80 to 100 cB P14 (Non-aluminized) D1(E) = 410 to 450 cB cBf = 640 cB (minimum) DO.1(E) - D1(E) = 60 to 90 cB D1(E) - D10(E) > DO.1(E) - D1(E) P14 (Aluminized) D1(E) = 430 to 470 cB cBf = 680 cB (minimum) DO.1(E) - D1(E) = 60 to 90 cB D1(E) - D10(E) > DO.1(E) - D1(E) P19 cBf = 575 cB (minimum) DO.1(10) = 410 cB (minimum) D1(10) = 335 cB (minimum) D1(10) - D10(10) = 75 to 120 cB P25 cBf = 600 cB (minimum) DO.1(10) = 400 cB (minimum) D1(10) = 325 cB (minimum) D1(10) - D10(10) = 50 to 80 cB METHOD 5221 5221-2 19 April 1968