Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D ELECTRODE LEAKAGE CURRENTS METHOD 5251 (Cathode-ray tubes) 1. Heater-cathode leakage current. In testing tubes having unipotential cathodes not connected to the heater within the tube, rated heater voltage shall be applied to the heater terminals and the instantaneous potential of any part of the heater shall be maintained at not less than 125 volts with respect to the cathode. The heater-cathode leakage current shall not exceed 10 µ A dc. 2. Grid No. 1 leakage current. With the control grid biased to cutoff, the leakage current between grid No. 1 and all other electrodes shall not exceed 3 µ A dc. 3. Grid No. 2 leakage current.

With the control grid biased to cutoff, the leakage current between grid No. 2 and all other electrodes shall not exceed 5 µ A dc. 4. Anode No. 1 leakage current. With the control grid biased to cutoff, the leakage current between anode No. 1 and all other electrodes shall not exceed 5 µ A dc. 5. Anode No. 2 leakage current. With the control grid biased to cutoff, the leakage current between anode No. 2 and all other electrodes shall not exceed 5 µ A dc. METHOD 5251 5251-1 19 April 1968