Downloaded from https://www.everyspec.com MIL-STD-1311D MAGNETIZATION METHOD 5256 (Cathode-ray tubes) 1. The tube shall be demagnetized and shall then immediately be scanned with a raster as specified in method 5226 (line width (electrostatic deflection) or line width (magnetic deflection)), as applicable. The change in line width following demagnetization shall not exceed 20 percent of the line width measured in accordance with method 5226 (line width (electrostatic deflection) or line width (magnetic deflection)), as applicable. The change of position of the undeflected spot shall not exceed 40 percent of the maximum allowable spot-to-center distance.
The entire tube shall then be exposed to a magnetic field of 500 gauss ± 10 percent, after which the tube shall not exceed the maximum limit(s) for the line width or spot-to-center distance specified. 2. During these tests the tube shall be located in exactly the same position in the mount. METHOD 5256 5256-1 19 April 1968