Downloaded from https://www.everyspec.com MIL-STD-1311D SIGNAL-T0-NOISE RATIO METHOD 5306 (Phototubes) Prior to testing, the tubes shall be kept in the dark at an ambient temperature of 24 ° C ± 3 ° C for not less than 1 hour. The specified light source shall be modulated at 90 Hz, using a square wave, or equivalent. The light spot on the cathode shall be as specified on the TSS. The tube output shall be fed into a low-pass amplifier calibrated in dB, the bandwidth of which is 1,000 Hz. Read the amplifier output with a VU meter calibrated in dB. The signal-to-noise ratio shall be determined as follows: a. Signal: with light on, adjust attenuator so that the VU meter is at zero.
Read attenuator setting. b. Noise: With light off, read as for signal. c. S/N ratio (in dB) = Signal minus noise. METHOD 5306 5306-1 19 April 1968