Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5401 ELECTRODE (Cathode-ray charge storage tubes) 1. Voltage breakdown. The maximum rated heater or filament voltage shall be applied with the potential of the control grid at maximum rating with respect to the cathode, and with the instantaneous potential of any part of the heater at its maximum rating with respect to the cathode (when unipotential cathode not internally connected to the heater is used) and with all other voltages equal to zero.

Maximum rated heater or filament voltage shall be 7.0 volts for tubes with heater or filament voltage rating of 6.3 ± 10 percent and 2.75 volts for tubes with maximum heater or filament voltage of 2.5 ± 10 percent. There shall be no recurrent breakdown between elements. 2. Voltage breakdown (single or multigun types). The control grid of each cathode-ray gun structure shall be adjusted for cutoff, and all other electrodes set at values within their maximum ratings which will provide the maximum stress between adjacent elements. There shall be no breakdown between elements. METHOD 5401 5401-1 19 April 1968