Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5406 DEFLECTION (Cathode-ray charge storage tubes) 1. Deflection factor (visual output tubes). With the test conditions specified, for visual output tubes the deflection factor (the ratio of the deflecting voltage to the corresponding deflection, in inches, as determined on each axis by deflecting the beam from a position 75 percent of useful scan radius, left or up from center, to a position 75 percent of useful scan radius, right or down from center) shall be within the limit(s) specified. 2. Deflection factor (electrical output tubes).

With the test conditions specified, for electrical output tubes, the deflection factor (deflecting voltage per diameter) shall be determined on each axis by deflecting the beam across the SSRD (storage surface reference dimension), see method 5405, and shall be within the limit(s) specified. 3. Deflection-factor uniformity (visual output tubes). In visual output tubes, for any axis, the deflection factors corresponding to 25 and 75 percent of the minimum useful scan radius shall be measured from the center of useful scan along the tube-face contour. Measurements on each axis shall be made on both sides from the center.

The value of the deflection-factor uniformity on each deflection axis shall be determined from the formula: %) 75 ( %) 75 ( %) 25 ( DF DF DF DFU = and shall be within the limit(s) specified. METHOD 5406 5406-1 19 April 1968