Downloaded from https://www.everyspec.com MIL-STD-1311D ELECTRODE LEAKAGE METHOD 5407 (Cathode-ray charge storage tubes) 1. Heater-cathode leakage. In testing tubes having unipotential cathodes not connected to the heater within the tube, rated heater voltage shall be applied to the heater terminals and the instantaneous potential of any part of the heater shall be maintained at not less than 125 volts with respect to the cathode. The heater-cathode leakage current shall not exceed 10 µ A dc. 2. Interelectrode leakage. With the control grid biased to cutoff, the leakage between the specific electrode and all other electrodes shall not exceed the limit(s) specified.
METHOD 5407 5407-1 19 April 1968