Downloaded from https://www.everyspec.com MIL-STD-1311D BLEMISHES, ELECTRICAL OUTPUT METHOD 5408A (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the blemish quality of a tube by measuring the following parameters: a. The blemish output signal levels relative to the output signal levels of adjacent areas. b. The size of the blemishes relative to the storage surface reference dimensions (SSRD) (see method 5405). c. The number of blemishes within a stated zone of the storage surface. d. The spacing of the blemishes. 2. Definitions. a.

A blemish is a localized imperfection of the storage assembly that produces an abrupt variation in the amplitude of the output signal. b. Static blemishes are blemishes whose presence is not a function of writing or erasing rates. c. Dynamic blemishes are blemishes whose presence is a function of writing or erasing rates. d. Light blemishes are blemishes which, under specified test conditions, result in output greater than that from adjacent storage surface areas. Signal polarity shall be such that writing results in increased output. e. Dark blemishes are blemishes which, under specified test conditions, result in output less than that from adjacent storage surface areas. f.

Saturation level is that output level beyond which no further increase in output is produced by further writing. g. Erasing rate is the time rate of erasing the stored information from one specified level to another. h. Decay time is the time interval during which the stored information decays to a stated fraction of its initial value. 3. Equipment. a. The reading and writing deflection system(s) shall produce a rectilinear (e.g., TV) type raster repeated at a rate specified in the TSS. b.

The TUT output shall be monitored on a CRT with a raster scan synchronized to the reading raster, and on an oscilloscope with provisions for selecting the video signal from any line of the reading raster and identifying the line on the CRT display. c. The output-signal amplifier shall be linear, compensated for the output impedance of the TUT, and have a frequency response that is flat within 1 dB between frequencies (f 1 ) and (f 2 ), to insure accurate reproduction of the screen quality of the TUT.

The low-frequency response shall be such that a pulse at the input of the amplifier, having a duration equal to the reading raster line-sweep duration, will be reproduced at the output with no more than 5 percent droop. f 1 = the read scan-line repetition rate (Hz). f 2 = D J R (MHz). METHOD 5408A 5408-1 12 December 1972