Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D 4. Precautions. The individual lines of the written raster are readily discernible at large spacings but blend into a relatively uniform brightness as the spacing between written lines is decreased. It is essential to determine the condition where the written lines first merge in the specified faceplate location(s), before measuring the raster height (h). Shrinking the raster beyond the first-merge condition may give a false indication of line separation and subsequently result in a second-merge condition which will give an erroneous raster height measurement. 5. TSS requirements. The TSS shall specify the following: 5.1 Equipment. a.

Sweep speed(s) and frame rate(s) (see 2a). b. Reading raster repetition rate (see 2b). c. When used, external focus and deflection component locations (see 2c). 5.2 Orthogonal write-read test method. a. Limits of operating voltages and conditions (see 3.1a). b. Percentage of saturation to result from writing beam (see 3.1d). c. Read output signal amplitude and decay rate (when applicable) (see 3.1e). d. Focus adjustment, only if it is to be other than optimum (see 3.1f). e. Location(s) from which the output signal is to be taken (see 3.1g). f. Relative amplitude of the peak-to-peak output signal at which the resolution is to be evaluated (see 3.1g). g.

Whether or not the test should be repeated with both rasters rotated 90 ° (see 3.1h). 5.3 Shrinking raster test method. a. Limits of operating voltages and conditions (see 3.2a). b. Percentage of saturation to result from writing beam (see 3.2d). c. Read output signal amplitude and decay rate (when applicable) (see 3.2e). d. Focus adjustment, only if it is to be other than optimum (see 3.2f). e. Location(s) at which the resolution is to be measured (see 3.2g). METHOD 5410 5410-3 12 December 1972