Downloaded from https://www.everyspec.com MIL-STD-1311D e. Adjust read output signal amplitude and decay rate (when applicable) to the values specified in the TSS. f. Unless otherwise specified in the TSS, focus shall be adjusted for optimum at the location(s) under test. g. While examining on the oscilloscope the output signal from the reading raster-line(s) at the location(s) specified in the TSS, decrease the spacing between the writing-raster scan lines, erasing as necessary, until the amplitude of peak-to- peak output signal, relative to the amplitude of the peak-to-peak output signal for widely spaced writing scan lines, is as specified in the TSS.
The orthogonal write-read resolution, at the amplitude specified in the TSS, is then equal to: N (WRSL/SSRD h amplitude specified. Where: N is the number of scan lines written. h is the written raster height as a fraction of the SSRD. (For multi-gun tubes, writing, reading, and erasing may be simultaneous or sequential. For single gun tubes, these operations are performed sequentially.) h. When specified in the TSS, the test should be repeated with both rasters rotated 90 ° . A single compromise focus condition shall be used. 3.2 Shrinking raster test method. a. Operating voltages and conditions shall be within the limits specified in the TSS. b.
Adjust operating conditions so that visual representation of the entire storage target is seen on the raster type display. c. Adjust writing conditions to produce and establish write saturation level. Writing raster lines shall be spaced such that there is no discernible overlap. d. Adjust writing beam current to obtain the percentage of saturation specified in the TSS. e. Adjust read output signal amplitude and decay rate (when applicable) to the values specified in the TSS. f. Unless otherwise specified in the TSS, focus shall be adjusted for optimum at the location(s) under test. g.
While examining the TUT output on the raster display at the location(s) specified in the TSS, decrease the spacing between the writing-raster scan lines, erasing as necessary, until the individual lines in the written-raster first merge into a uniform brightness. The shrinking raster resolution is then equal to: N (WRSL/SSRD h merged raster. Where: N is the number of scan lines written. h is the written raster height as a fraction of the SSRD. (For multi-gun tubes, writing, reading, and erasing may be simultaneous or sequential. For single gun tubes, these operations are performed sequentially.) h. When specified in the TSS, the test should be repeated with both rasters rotated 90 ° .
A single compromise focus condition shall be used. METHOD 5410 5410-2 12 December 1972