Downloaded from https://www.everyspec.com MIL-STD-1311D UNIFORMITY, LUMINANCE, VISUAL OUTPUT METHOD 5414 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to measure the evenness of luminance from the TUT. Four separate methods using combinations of writing and erasing, and under static and dynamic operations are given. 2. Definitions. Saturation level is that level of luminance beyond which no increase in luminance is produced by additional writing. The tube can be written to saturation level by writing up the entire viewing area with the erase pulse amplitude set at zero and then cutting off the write beam. 3. Equipment. a.

A photometer shall be used to measure the luminance of the TUT over a circular area 10 ± 5 mm (approximately .4 ± .2 inch) in diameter in the following four methods (A, B, C, and D). In methods C and D, the photometer shall have a response time less than 0.1 second. (Such characteristic could be achieved through the use of a peak holding device coupled to a fast response light sensor.) b. A stop watch or other elapsed time indicator is required in method C. c. A deflection system shall produce a raster on the TUT with linear sawtooth deflections in orthogonal directions.

(1) In methods A and B, the raster shall be overmerged and its size adjusted such that the writing beam writes on all parts of the area specified in the TSS. (2) In methods C and D the frame sweep shall be at a rate of 2 inches (50.8 mm) per second and the line sweep shall be at a rate of .016 inch (0.41 mm) per microsecond, or as specified in the TSS. In methods C and D, the frame and line periods shall be no greater than 125 percent of the resulting sweep times, or as specified in the TSS (for example: with a 4-inch by 4-inch (101.6 mm by 101.6 mm) raster:

Frame-sweep time = 2 seconds Frame period = 2.5 seconds maximum Line-sweep time = 250 microseconds Line period = 312.5 microseconds maximum). d. The writing control circuits shall be adjustable, but once adjusted in methods A, C, and D, shall maintain a constant unblanking level during the active periods of the write cycle. In method B, the writing control circuit shall be adjustable to permit writing to saturation level as specified. e. A random noise generator is required for method C. It shall provide a white gaussian noise signal with a bandwidth of approximately 20 Hz to 500 kHz or as specified in the TSS, at an amplitude specified in the TSS. METHOD 5414 5414-1 12 December 1972