Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D g. Using the line select feature of the equipment, determine the following parameters: (1) Maximum white signal, I W max. (2) Minimum white signal, I W min. (3) Maximum black signal, Ibk max. (4) Minimum black signal, Ibk min. h. Calculate average signal output current I av from the following expression: 2 ) ( ) ( max min min max Ibk Iw Ibk Iw I av + = i. Calculate output signal uniformity factor S w from the following expression: av w I Ibk Ibk Iw Iw S ) ( ) ( min max min max + = 4. Precautions.

Determination of the levels called for in 3g above, shall be done as rapidly as possible to minimize errors due to change in signal level caused by signal decay. 5. TSS requirement. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) The area of the target within which the uniformity is to be measured. (2) Erase procedure. b. If values other than those specified in this test method are required, the TSS shall specify: Reading time, see 3c. METHOD 5413 5413-2 12 December 1972