Downloaded from https://www.everyspec.com MIL-STD-1311D d. Using the noise signal within specified limit(s), adjust the unblanking pulse, erase duty cycle, and erase amplitude within specified limit(s) to achieve a stabilized writing and erasing cycle whereby: (1) The slowest erasing portion of the specified area is completely erased immediately prior to being rewritten. (2) The noise signal is writing to the peak luminance level specified in the TSS. (3) The unblanking level is adjusted just below the point at which storing would occur in the absence of the noise signal. (4) The display uniformity is optimized. NOTE:

The stability of the writing and erasing cycle shall be verified by observation over a period of 2 minutes or as specified in the TSS. e. Without any adjustments, find the fastest erasing area. Measure the time interval (T1) between peak luminance level and complete erasure. f. Calculate the luminance decay uniformity factor for the specified value of (T2) from the formula: Luminance decay uniformity factor (DDWE) = 2 1 2 T T T Where: T2 is the time interval between peak luminance level and complete erasure of the slowest erasing area. T1 is the time interval between peak luminance level and complete erasure of the fastest erasing area. 4.4 Method D.

This method measures luminance uniformity factor-dynamic/write erase (DWE) under conditions of dynamic writing and erasing in which the writing signal is an unblanking pulse. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write the entire area specified in the TSS to saturation level. c. Stop writing. Use the erase pulse width and frequency within the ranges specified in the TSS. Slowly increase the erase pulse amplitude until the last portion of the specified area has just been erased within the frame period specified in the TSS. d.

Adjust the unblanking pulse, erase duty cycle and erase amplitude within specified limit(s) to achieve a stabilized writing and erasing cycle whereby: (1) The slowest erasing portion of the specified area is completely erased immediately prior to being rewritten. (2) The unmodulated, unblanking pulse is writing the brightest writing area to the peak luminance level (B2) specified in the TSS. (3) The display uniformity is optimized. NOTE: The stability of the writing and erasing cycle shall be verified by observation over a period of 2 minutes or as specified in the TSS. e. Without further adjustments, find the peak luminance level of the lowest brightness writing area.

Measure and record as B1. f. Calculate the luminance uniformity factor (DWE) for the specified value of (B2) from the formula: Luminance uniformity factor (DWE) = 2 1 2 B B B METHOD 5414 5414-3 12 December 1972