Downloaded from https://www.everyspec.com MIL-STD-1311D 5. Precautions. a. To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. b. Luminance measurements shall be made under carefully controlled conditions. Even under photometric laboratory conditions, accuracies within ± 5 percent are difficult to achieve. In the average production environment, accuracies within ± 10 percent may be expected.
A major source of this error is the difference in ability of the different photometers to match the CIE (Commission Internationale de l'Eclairage) Standard Observer Luminosity Response. This error source is especially important when a large portion of the luminance is in the blue and red regions where deviations are most prevalent. c. Where required to write the display area to saturation level, do not overdrive the write gun beyond the level necessary to reach saturation. 6. TSS requirements. a. In addition to the operating conditions for the TUT, and the specific method(s) of test to be used, the TSS shall specify the following when applicable:
(1) The area of the display within which luminance uniformity is measured. (2) Amplitude of the random noise signal (see 3d, 4.3d). (3) Luminance level (Ba) (see 4.1d). (4) Luminance level (Bc) (see 4.2c). (5) Erase pulse widths and frequencies (see 4.3c, 4.4c). (6) Time period (T2) (see 4.3c). (7) Unblanking pulse and erase pulse amplitudes (see 4.3d, 4.4d). (8) Peak luminance level (see 4.3d(2)). (9) Peak luminance level (B2) (see 4.4d(2), 4.4f). (10) Time for erasure (see 4.4c). b. If values other than those specified in this test method are required, the TSS shall specify the following when applicable: (1) Frame and line sweep rates (see 3c).
(2) Ratio of sweep periods to sweep times (see 3c). (3) Random noise signal bandwidth (see 3d). (4) Erase pulse widths (see 4.1c, 4.2c). (5) Stability period (see 4.3d, 4.4d). METHOD 5414 5414-4 12 December 1972