Downloaded from https://www.everyspec.com MIL-STD-1311D GRAY SCALE RESPONSE, VISUAL OUTPUT METHOD 5419 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the response of the TUT to a gray scale test pattern input. The response is determined by examining the output signal resulting from writing with a staircase voltage input signal. This method is intended primarily for tubes whose application includes TV display. 2. Equipment. a. A photometer shall be used to measure the luminance of the TUT over a circular area 10 ± 5 mm (approximately .4 ± .2 inch) in diameter. b.
A deflection system shall produce a raster from a linear sawtooth field sweep at a 60 1/ Hz repetition frequency, and a 53 1/ microsecond linear sawtooth line sweep having a 63.5 1/ microsecond period, or as specified in the TSS. c. A video signal generator shall produce a gray scale test pattern consisting of a 10-step linear staircase voltage synchronized with the linear sawtooth line sweep with individual step widths of 5.3 microseconds, with adjustable entire staircase voltage amplitude from 0 to 15 V peak-to-peak, with each step having maximum voltage overshoots of 1.0 percent maximum, undershoots of 1.0 percent maximum, and droops of 1.0 percent.
Any of these parameters may be alternatively specified in the TSS. d. An erase system shall produce rectangular erase pulses with a width of 0.5 1/ millisecond and a frequency of 60 1/ Hz synchronized with the linear sawtooth field sweep, or as specified in the TSS. Viewing screen current may be reduced or cut off during the erase period as specified in the TSS. 3. Procedure. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write the entire area specified in the TSS to saturation level. c. Stop writing. Use the erase pulse width and frequency specified in 2d above.
Starting from zero, adjust the erase pulse amplitude until the last portion of the specified area has just been erased. d. Continue erasing. Apply the video signals specified in 2c above to the write gun and adjust the linear staircase voltage amplitude and the unblanking level until a minimum of five distinguishable luminance levels (including black and white), or the number specified in the TSS, are obtained in the specified area. The erase pulse amplitude may be readjusted to obtain the best gray scale performance. e. The brightest portion of the test pattern within the specified area shall be at least equal to the peak luminance level specified in the TSS. f.
To be counted as a luminance level, each step must be distinguishable from the adjacent step along the entire transition length. If two or more adjacent steps cannot be distinguished from each other along their entire length, they shall be counted as one level. 4. Precaution. To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. ___________ 1/ Typically, 525-line television system. METHOD 5419 5419-1 12 December 1972