Downloaded from https://www.everyspec.com MIL-STD-1311D 3.2 Method B. This method measures the gray scale response under static, single-write conditions. a. Operating conditions shall be as specified in the TSS. b. Read the area specified in the TSS and display the output on both the oscilloscope and monitor. The orientation of the reading raster shall be such that each line of the reading raster, within the specified area, scans across all the steps of the stored gray scale pattern. c. Operate the TUT with storage time at maximum, or as specified in the TSS. d. Erase and/or prime the TUT until the lightest area is just black. e.
Write the gray scale video test pattern with the write scan size adjusted so that the pattern covers the area specified in the TSS. Writing conditions should be set so that the lowest amplitude step is just written and the maximum number of steps can be seen on the oscilloscope. f. Stop writing. Count the number of steps of the gray scale test pattern visible in the output of the oscilloscope. This is the gray scale response (static). To be counted, each step must be distinguishable on the oscilloscope display from the adjacent step along the entire step transition within the specified area. Use the line selector on the oscilloscope to check the entire specified area. 4. Precautions. a.
The gray scale test signal (input) is permitted to contain more steps than are required to be visible in the output. An excessive number of input steps should be avoided, however, as this makes determination of the transition between steps in the output signal difficult. b. Because of the non-linear characteristics of these devices, the number of gray scale steps which can be reproduced by the TUT is dependent on such operating conditions as applied target voltage and the selected scan rate. Therefore, each specification for gray scale response shall include the specific operating conditions for which the response is required. 5. TSS requirements. a.
In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) Area to be examined. (2) The minimum number of gray scale steps that must be counted in the output on the oscilloscope. (3) Whether the test is to be performed under dynamic conditions by method A or under static conditions by method B. (4) The storage time if method A is specified. b. If values other than those specified in this test method are required, the TSS shall specify: Storage time for method B. METHOD 5420 5420-2 12 December 1972