Downloaded from https://www.everyspec.com MIL-STD-1311D READING TIME, USABLE, ELECTRICAL OUTPUT METHOD 5421 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the time period over which a usable output signal is obtained from an electrical output storage tube during continuous readout. Bistable devices are excluded from this method. 2. Definitions. a. Usable reading time is the time period over which a usable output is obtained during continuous readout. b. Saturation level is that signal output beyond which no further increase in signal is produced by further writing. 3. Equipment.
3.1 The deflection system shall produce writing and reading rasters in the TUT, each with linear sawtooth deflections in orthogonal directions. 3.2 The output of the TUT shall be monitored on the CRT with a raster scan synchronized to the reading raster and on an oscilloscope with provision for displaying the video output from any line of the reading raster. 3.3 The output-signal amplifier shall be linear, compensated for the output impedance of the TUT, and shall have an essentially flat response over a bandwidth wide enough to insure accurate display of the uniformity capabilities of the TUT.
3.4 The writing control circuits shall be adjustable, but once adjusted for this test shall maintain a constant unblanking level during the active periods of the write cycles. 3.5 A stop-watch or other clock suitable for recording the measured time interval is required. 4. Procedure. 4.1 Operating conditions shall be as specified in the TSS. 4.2 The oscilloscope display shall be synchronized to the reading line scan and shall display any line within the area specified in the TSS. 4.3 Without erasing, write the entire area specified to the saturation level. 4.4 Stop writing.
Use the erase procedure specified in the TSS and adjust conditions to obtain a single erase cycle that will cause the fastest erasing portion of the specified area to just be erased. Immediately proceed to 4.5. 4.5 Use a pattern of 10 black and 10 white bars, all of approximately equal width, orthogonal to the read line scan, and write with overlapping scan lines until the fastest writing portion of the specified area just reaches saturation level. 4.6 Stop writing. Read while displaying the bar pattern on the monitor, and determine the region within the specified area in which contrast degrades most rapidly.
Set the oscilloscope to display a single line scan approximately through the center of this region and note the position along the scan line corresponding to the approximate center of this region. 4.7 Repeat 4.3, 4.4, and 4.5. 4.8 Stop writing. Read and immediately start stopwatch or other suitable device for recording the time interval. 4.9 With respect to figure 5421-1, determine the output signal level through the fastest decaying portion of the specified area at the beginning of the time interval, I S (O).
4.10 Under continuous reading conditions, determine the elapsed time required for the signal level to drop to one half of the initial value determined in 4.9 or to the value(s) specified in the TSS. 4.11 The usable reading time (T R ) is the elapsed time interval determined in 4.10; the initial output signal level (I S (O)), shall also be specified. METHOD 5421 5421-1 12 December 1972