Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D RASTOR CUTOFF METHOD 5431 (Vidicons) 1. The tube shall be tested in a camera system with associated monitors as shown on the block diagram of figure 5426-1. 2. Align the tube in accordance with method 5437. 3. With test conditions as specified, remove blanking voltage from grid No. 1 and adjust Ec1 until test pattern just disappears as observed on monitor. Ec1 shall be within the limit(s) specified. METHOD 5431 5431-1 28 March 1975