Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5432 LAG (Vidicons) 1. The tube shall be tested in a camera system with associated monitors as shown on the block diagram of figure 5426-1. 2. Align the tube in accordance with method 5437. 3. Lag test. a. Equipment. (1) Calibrated light source of 2,856 ° K ± 20 ° K color temperature. (2) Suitable filters and apertures to obtain specified faceplate illumination. (3) Motor-driven light chopper capable of interrupting the path of light four times per second.

The light chopper shall provide light to the vidicon target for .20 second and interrupt for .05 second such that the vidicon target receives light for about 12 TV fields and receives no light for about 3 TV fields. (4) An oscilloscope capable of monitoring the signal output including the dc component. b. Block diagram (see figure 5432-1). c. Procedure. (1) The tube shall be tested in camera with associated monitors as shown on the block diagram of figure 5426-1. (2) Align the tube in accordance with method 5437. (3) Set up vidicon for optimum operation as specified for center resolution.

(4) The light chopper is turned off and the calibrated light source is adjusted to give 2,856 ° K color temperature. (5) Vary the neutral density filter and the position of the light box on the track to give the specified signal output level with the specified dark current (target voltage) setting. (6) Switch vidicon signal electrode output directly to the dc input of the oscilloscope. A minimum scope sensitivity of 0.05 V/cm is required for satisfactory display. Adjust polarity of scope so that the white signal is positive. (7) Cap the vidicon and adjust the vertical centering control to obtain 0 percent on the scope scale.

(8) Uncap the vidicon and adjust the scope gain control to obtain a white signal equal to 100 percent (4 cm to 5 cm). (9) With light incident on vidicon faceplate, carefully adjust the scope triggering level and stability controls to "lock-in" the scope display. (10) Turn on the chopper motor and carefully adjust the sweep multiplier control to "lock-in" the lag curve near the center of the display. (11) Adjust the phasing control of the synchronizing circuitry until the last two fields of the white signal are identical. This indicates that the "light-cutoff" point of the chopper has been phased to occur during the vertical blanking period. METHOD 5432 5432-1 28 March 1975