Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5436 SENSITIVITY (Vidicons) 1. The tube shall be tested in a camera system with associated monitors as shown on the block diagram of figure 5426-1. 2. Align the tube in accordance with method 5437. 3. The target voltage shall be adjusted to yield the specified target current. 4. Project specified faceplate illumination on vidicon target. The lamp current of the light source shall be adjusted for a color temperature of 2,856 ° K ± 20 ° K, or as specified. Sensitivity is the target current under these conditions minus dark current and it shall be within the limit(s) specified. METHOD 5436 5436-1 28 March 1975