Downloaded from https://www.everyspec.com MIL-STD-705C 425.1.3.2 Test. a. Start and operate the prime mover such that the generator is at rated speed. Adjust the external excitation supply to produce rated voltage at the generator terminals with no load. b. Record all intrument readings (see figure 425.1-II). c. Start the oscillograph. Allow sufficient time to record the zero position of the current trace, the open circuit voltage, and the timing wave. d. Close the short-circuiting switch. Allow the oscillograph to record the transient and sustained short-circuit current and voltage. e. Record all instrument readings when sustained short-circuit conditions are achieved. f.
Repeat steps a thru e two additional times. NOTE: For a polyphase generator, it is permissible to record oscillographically the short-circuit current in one phase only. 425.1.4 Results. a. Working directly on the oscillogram, start with the first peak in the current wave following the application of the short-circuit, and number this peak “1” (see figure 424.1-III). Number subsequent peaks consecutively until steady-state conditions occur. Draw a curve through the even numbered peaks and another through the odd numbered peaks. These two curves are mild the “envelope”.
Construct straight lines from each peak to a point on the opposite half of the envelope which is Ѕ the horizontal distance between the preceding and the following peaks on the opposite side of the zero axis. Starting at the first peak that can be identified (either peak no. 1 or peak no. 2), measure (in millimeters or other comparable units) the distance between envelope lines along the lines just constructed. Prepare a table of these distances (see figure 425.1-IV). Measure the perpendicular distance between envelope lines at steady-state b. c. d. e. and enter this into the table prepared in step d above. Steady-state is determined by the envelope lines (they are parallel at steady-state) .
Subtract the steady-state distance from each of the other distances to obtain the fourth column of the table. Using semi-log graph paper with the linear axis labeled “peaks” and the f. g. log axis labeled “millimeters” (or the unit used in measuring the distances in steps d and e above), plot each of the distances obtained in the fourth column. Draw a smooth curve through the points ignoring obvious measurement errors. This curve is identified as “Curve A” in figure 425.1-V. Extend the straight line portion of “Curve A” to the edge of the paper. Thi S extension is identified as “Curve B” in figure 425.1-V.
On the oscillogram measure the distance along the zero axis between the “t = 0” line (the point at which the short circuit was applied) and the line drawn from the no. 2 peak. Enter this distance on the work sheet. In the example, the distance was found to be 7.0 millimeters. h. i. j. Method 425.1b 2