Downloaded from https://www.everyspec.com .!., ., MIL-STD-81OB 15 June 1967 (a) On-1ine, contiguous filter,eqWliZAtion/analysis system having a bandwidth . B = 50 cps, maximum. (b) Swept frequency analysis systems characterizedas follows: 1. Constant bandwidth analyzer. a. Filter bandwidth as follows: B = 20 cps, maximum between 20 to 200 cps B = 50 cps, maximum between 200 to 2,000 cps b. Analyzer averaging time = T = 2 RC = 1 second, minimum, where T = True averaging time and RC = analyzer tire constant c. Analysis sweep“rate (linear)=R= B or=, (cps/second)maximum, whichever ~ 8 is smaller. 2. Constant percentage bamdwidth analyzer. a.
Filter bandwidth.pfc=one-third octave maximum (.23 fc) where p=percentage and f= = analyzer center frequency. b. Analyzer averaging time=k>, minimum pfc c. Analysis sweep rate (logarithmic)=R=pfc or (pfc)2 ,. - ( (cPS/Se,Ond),maximum,whichever GT is smaller. (c) Digital power spectral density analysis system employing quantization techniques providing accuracies correspondingto the above approa:h. The composite G-rms test level shell not be less than the value given on figure 514l-b or 51b.1-5 for each test curve. Accelerometers ) employed for test level control shall be mounted in accordance with 4,1.
Where more than one accslemineteris employed for test level control, the power merage of the several accelerometer signals shall be used as the test level signal control. 4.6 Procedure 1. - 4.6.1 ~. - Proceed the same as in 4.5.1.1, k:5.1.2, and h.5.l.3. The test level shall be according to one sp.ecifieacurve C through H, J, L, M, Z, AS, or AT from figures 51L.1-1, 514.1-2, or 514.1-3 as applicable for that equipment category. Test time schedules shall be as specified for part 1 of Procedure I in the applicable table. 514.1-7 lCiYITiOD 51h.1 20 October 1969