..-:..A ?,:.-’%. :=,,..:: ;.:.=. .:7;,:.., ; ,;,,: .~~:- .... . ~ ::...::::,.::--- ................ .,-.. ,>.. .,, ,. &T5f~? .-,+-. ,,. “-+-.+;.;..? ,;... *:T.,.: .. ,-. ,,’. . , . x.-,..,,.. J J-- :.:-,’92,. ... ,., MIISi?O+ll)ByJ&i~i !,.. :,:,, ,:::..$; ~:;-: , , .,-?.:.. . ~ ..,rg >. .,,,:;:.. .,.,..., :.15;,J@e?j967j$:?,i , . .-J +.$+ ,:’. . -:: ;’..; . ,...,,. .*+#x,.; ,*.., ... ,.. ---..; ,-..:.,- Downloaded from https://www.everyspec.com .,, ,{ ,., ... most“severe”resonant frequencies shell be chosen for the dwell test.“;:: c If a ch”ang~~i”n~ the’resohut frequencyoccurs during the test, its time of occurrenceshall-be‘fecorded‘--.
and imme;$iat ely the frequency‘shallbe adjusted to maintain the peak resontice-:condi~ tion. The final resonant frequencyshall be recorded. ..:... ;,, :4 ... ~.. . . . . h.5:.l.3 cycling. - The test item shall’be vibrated along each axis in accordance with the!applicabletest levels, frequency rmge, and times from tables.514.1-1 through 51k.1-VII and figures 514.1-1 through 514.1-’7. The frequency of applied vibraticm shall be swept over the specified range logarithmicallyin accordance vith figure’51h.1-10. The specified sweep time is that of an ascending plus a descendingsweep and is ttice the ascending sweep time shown on figure 514.1-10 for the specifiedrange.
Linear sweep rates may be substituted for the logarithmic sweep rate. When linear sweep rates , are used, the total frequency range shall be divided into logarithmicfrequencybands having similar time intervals such that each time interval is the time of ascending plus a descending sweep for the correspondingband. The sum of these time intervals shall equal the sweep time specifiedfor the applicable frequencyrange. The linear sweep rate for each band is then determined by dividing each bandvidth in CPS by cme- half the sweep time in minutes for each band. The logarithmic frequencybands may be readily determined from figure 514.1-10.
The frequency bands and linear sweep rates shown in table 51b.1-IX shall be used for the 2 (or 5) to 500 cps and 5 to 2,000 CPS frequency ranges. For test frequencyranges of 100 cps or less, no correction of the linear sweep rate i5 required. -. h.5.2 Random vibration test. - The test item shall be subjectedto rtidom vibra- tion along each of three mutually perpendicular axes according to one specified curve Allthrough AP from the applicable figure 51b.1-k or 51b.1-5. Test times shall be according to the applicable schedule from tables 514.l-IV or 514.1-V. The instantea~ ecus‘randomvibraticm accelerationpeak+ WY be limited to three times the rum accele- .. ration level.
The power spectral density of the test centrol signal shall not deviate from the”specified requirementsby mere than +40, r -30 Percent (+/-1.5 dB) below 500 CPS and ?100, -50 percent (+/-3 dB) between 500 CPS and 2,000 CPS, except thet devia- tions as large as +300, ‘T?’Percent (+/-6 dB) shall Oe allowed over a cumulativeb~d- wi~th of 100 cps, maximum, between 500 and 2,000 cps. ,.! . . .. . ,:i;