,,, , . . MIL-STD-81OB .:. Downloaded from https://www.everyspec.com 15 June 1967 /- ,. ~,. setup. Whenever possible,the test load shall be distributed uniformly on the vibra- tion exciter table in order to minimize effects of unbalanced loads. Vibration ampli- tudes end frequencies shall be measured by techniques that will not significantly . affect test item input control.or response. .: The input control sensing device(s) shall be rigidly attached to the vibration table or to the intermediate structure, if used, at or as near as possible to the attachmentpoint(s) of the test item. 4.3 Combined temperature-vibrationtest.
- Tests shall be performed under room ambient conditions unless a high or low temperature vibration test is specified, in which case the temperatureextremes and time duration tiso sh~l be specified. 4 .b Combined sinusoidalcyclinu and random vibration test. - The sinusoidal cycling and random vibration tests shall normally be perform.edseparately. If analyses of actual or predicted data indicate a simultaneous sinusoidal and random vibration environment,the procedure for a combinedtest shall be specified. 4.5 Common test techniques. - 4.5.1 Sinusoidal vibration tests. - The vibration shall be applied along each of the three mutually perpendicular axes of the test item.
The vibratory aczeleration levels or double amplitudesof the specifiedtest curve shall be maintained at the test item mounting points. When specified, for sinusoidalresonance search, resonance dwell, and cycling tests of items weighing more than 80 pounds mounted in airplanes,heli- copters,and missiles, the vibratory accelerationsshall be reduced +/-1 g for each 20 pound increment over 80 pounds. Accelerationderating shall apply only to the highest test level of the selectedcurve, but in no case shall the derated test level be less than 50 percent of the selected curve (see note 1 of applicable table 51b.1-1 through ,r. 51k.1-v).
For equipmentweighing over 100 pounds and transported by aircraft, resonance search, resonance dwell, and cycling tests may be frequency and accelerationderated (see notes 1 and 2 of table 51b.l-VII). When packaged items are always grouped together cm mechanized loading platforms or pallets, accelerationand frequency derating may be based on the total load on the pallet. When the input vibration is measured at more than one control point, the cont?ol signal shall be the average of all the accelero- meters unless otherwise specified. For massive test “items,fixtures and large force exciters, it is recommendedthat the input control level be an average of at least three or more inputs.
4.5,1.1 Resonance search. - Resonant frequenciesof the equipment shall be deter- mined by varying the frequency of applied vibration slowly through the specified range at reduced test levels but with sufficientamplitude to excite the item. Sinusoidal resonancesearch may be prefomed using the test level and cycling time specified for sinusoidalcycling test, provided the resonance search time is included in the required cycling test time of 4.5.1.3. 4.5.1.2 Resonance dwell. - The test item shall be vibrated along each axis at the most severe resonant frequenciesdetermined in b.5.1..1. ‘ll=tlevels, frequencY rwzes.
and test times shall be in accordance with the applicable conditions from tables 511!.1-1 through 514.1-V and figures 514.1-1 more than four significantresonant through 514.1-7 for each equipment catceorY. If frequenciesare found for any one axis, the four . . 514,1-5 METSOD ji4.1 20 October 1969 .