U.S. Department of Defense MIL-STD-810C — MIL-STD-810C Environmental Test Methods Standard — PDF Manual Download

Downloaded from https://www.everyspec.com MIL-STD-81OC 3.3.2.1 Test level reduction, ~, of Go. and Go, due to gun standoff para- figure 519.2-5, shall be ,allowed for the case of gun configurationswith muzzles mounted a perpendicular distance from the aircraft structure. meter (h/c). A reduction of Go~, Gor in accordance with the criteria of ,3.3.2.2 Test level reduction] ~, of Gos and Go= due to free air configuration. A reduction of GOS, Gor shall be aliowed for thos,ecases in which the gun protrudes clear of and in front.of the aircraft s~ructure as shown in figure 519.2-6. The reduction shall be 6 dB; otherwise AM = O dB.

3.3.2.3 Test level reduction, AR, of GOS and Gor as a function of R5. The curve of figure 519.2-7 provides means by which Gos or Gor shall be reduced as a function of RS. 3.3.2.3.1 Determination of the depth parsmeter (Rs). The depth parameter represents the shortest distance of the equipment mounting points.to the ai~craft surface as shown in figure 519.2:8.- The measurement”shal1 be taken from the equipment or mounting points that are nearest to the aircraft surface. If Rs is unknown or cannot be estimated, Rs shall be set at 3 inches or less. 3.3.2.4 Test level reduction, Aw, of Go and Gor due to equipment mass loadinE.

Figure 519.2-9 provides graphical means by.which GOS, GOI-may be reduced as a function of equipment weight. For those equipments attached directly to primary structure“th~oughvibration isolators; AW = O. For equipments associated with secondary structure, AW = O. 3.3.3 Determination of the distance parameter (D). The distance par~eter represents the vector distance, measured (or estimated) from the gun muzzle to the mean distance between equipment support points. Where equipment support points are indeterminate,the equipment center of gravity shall represent the terminal point of D.

The vector D is generated from the orthogonal distances referenced to the fuselage station, the water, and the butt line data. The D vector and the computational form is shown in figure 519.2-8. 3.3.3.1 Multiple guns, closely grouped. For configurationsinvolving multiple guns, the origin of D is determined from the centroidal point of the gun muzzles. Figure 519.2-10 shows the origin location for a typical four-gun staggered array. 519.2-5 METHOD 519.2