U.S. Department of Defense MIL-STD-810C — MIL-STD-810C Environmental Test Methods Standard — PDF Manual Download

Downloaded from https://www.everyspec.com MIL-STD-81OC 3.4.2 Application of lH(f)12. From table 519.2-II select the transfer function associated with the mounting category. These categories are represented by two sets of curves (figures 519.2-18 and 519.2,-19)and allow envelope adjustments owing to the weight of the equipments. The first set of curves (figure 519.2-18) involves a selection of K as a function of equipment weight (there are exceptions to this rule noted in table S19.2-11). This value, K, is then inserted into the f/fnl para- meter as indicated at the bottom part of the transfer function curves.

Normally, W is equivalent to the total equipment‘weighton the shelf panel, beam or truss. If stacked arrays of equipments are involved (consoles,.etc.) then W is the total weight of the assembly and fnl is the average value Of the shelf array. Finally, in dB form algebraicallyadd lH(f)12 to Gs and Gr at a suf- ficient number of their corresponding.frequencies to insure a smooth spec- tral plot. In no case shal1 there be less than fifteen plot points over the test spectrum. I 4. TEST IMPLEMENTATION. Test procedures used shall be as specified ii the equipment specification or test plan. ) 4.1 Test item operation.

Unless otherwise specified, the test item shall be operated during application of vibration so that functional effects caused by these tests may be evaluated. When a test item performance test is required during vibration and the time required for the performance is greater than the duration of the vibration test, the performance test shall be abbreviated accordingly. At the conclusion of the test, the test item shall be operated and the results obtained in accordance with General Requirements, 3.2. The test item then shal1 be inspected in accordance with General Requirements 3.2. 4.2 Mounting techniques.

In accordance with General Requirements, 3.2, the test item shall be attached to the vibration exciter table by its nor- mal mounting means or by means of a rigid fixture capable of transmitting the vibration conditions specified herein. Precautions shall be taken at the mechanical interfaces to minimize the introductionof undesirable responses in the test setup. Whenever possible, the test load shall be distributed uniformly on the vibration exciter table in order to minimize effects of unbalanced loads. Vibration amplitudes and frequencies shall be measured with instrumentationthat wil1 not significantlyaffect the test item inrmt control or response.

The input control accelerometer(s) shall be rig;dly attached to structure, if used, at or as of the test item. tie vibration table near as possible to or to the intermediate the attachment point(s) 519.2-11 METHOD 519.2