Downloaded from https://www.everyspec.com MIL-STD-81OC 7.1.3 Determination of the locator frequencies f. and fo;. From 3.3.4.2 select: f. = 200 Hz for the sinusoidal surface, f. = 300 Hz for the low frequency random surface and from figure 519.2-11 select (from the curve at W = 75 lbs): fo- = 900 Hz. 7.1.4 Determination of the sinusoidal surface, Gs. Refer to figure 519.2-2. It is useful to draw lines on the figure hence it is advantageous to make a copy. On the copy draw a line in the zero dB plane parallel to the constant D lines at D = 48 inches. Note that this line intersects the f/f. parsmeter. From the intersectionsdraw vertical lines down to the heavy, constant f/f.
lines of the prediction surface. These distances down are now transferred to the left hand dB scale (3.3.4). Recalling that f. = 200 Hz for the sinu- soidal surface arrange a table of values of Gs VS f/f as fOllOwS: 0 0 f G~(dB re. ‘as) G:s = 796 g2/28.2 grins f/f 2.0 400 - 11.6=55.07 g2 = 7.42 grins 1.6 320 - 12.3 = 46.86 g2 = 6.85 grins 1.2 240 - 13.B = 33.19 g2 = 5.76 grins 1.0 200 - 15.5 = 22.43 g2 = 4.74 grins 0.8 160 - 18.6 = 10.98 g2 = 3.31 ‘grins 0.6 120 - 20.5 = 7.09 g2 = 2.66,grms 0.4 80 - 22.0 = S.02 gz = 2.24 grins 0.2 40 - 23.0 = 3.9B gz =’1.99”grins For plotting purposes it is convenient to express the values of Gs relative to Gs at f/f. = 2.O; which is Gs max.
This is done by subtracting Gs Max (-11.6 dB) from all of the values. MEIHOD 519.2 519.2-16 I