U.S. Department of Defense MIL-STD-810C — MIL-STD-810C Environmental Test Methods Standard — PDF Manual Download

Downloaded from https://www.everyspec.com MIL-STD-810C B f/f o f G~ -G~.~ax (dB~) O dB re. 55.07 g2 = 7.42.grins 2.D 400 1.6 320 -’0.7 1.2 240 - 2.2 1.0 200 - 3.9 0.8 160 - 7.0 0.6 120 - 8.9 0.4 80 - 10.4 0.2 40 - 11.4 Before proceeding to the next step it is instructive to pause and observe that were we concerned with defining a test spectrum for secondary structure (3.4) it is now only necessary to attach the required dBH column to the ri8ht of the present dBs column and add the values to obtain the response, dBys. 7.1.4.1 Setting up the sine spectrum. Plot the envelope of Gs as a function of frequency (see,3.3.4.1) and designate the fundamental and harmonics as follows: 1.

Set r = fl = 70 Hz, f2 = 2(70) = 140 Hz, f3 = 3(70) = 21o HZ and f4 = 4(70) = 280 HZ 2. Pick off the four correspondingvalues of dBs frOm the plot (re. 55.07 g2 or 7.42 grins) @ 70 Hz Gsl = - 10.7 dB = 4.69 g2 = 2.16 grins @ 140Hz G~2 = - 8.1 dB = 8.53 g2 = 2.92 grins @ 210 Hz G~3 = - 3.9 dB = 22.43 g2 = 4.74 grins @ 280 HZ Gs4 1.3 dB = 40.82 gz = 6.39 grins 519.2-17 MS’IHOD519.2