7 Press SET button (Fixing of the upper limit position) The upper limit position is fixed and the setting position is displayed for two seconds. Then proceed to lower limit position selection display. [EXAMPLE] ” (lit for two seconds) И ” (shows current setting) AIR SELECTION button can switch the air outlets. 1. Stop the air conditioner. 2. Select the airflow from AIR SELECTION button on the unit display. A In case of selecting to upper airflow. Press the AIR FLOW SELECTION button once. UPPER AIR FLOW LED will light for ten seconds. B In case of selecting to upper and lower airflow.

When UPPER AIR FLOW LED is lit by pressing AIR FLOW SELECTION button, press AIR FLOW SELECTION button once again. UPPER AIR FLOW LED will turn off. 8 Press or button (Selection of lower limit position) Select the lower limit position of louver. “position 1” is the most horizontal, and “position 6” is the most downwards. “position --” is to return to the factory setting. If you need to change the setting to the factory setting, use “position --”. HOW TO OPERATE VENTILATION (WHEN A VENTILATOR IS INSTALLED) (horizontal) When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless of the operation of the air conditioner.

When the ventilator is set to “VENTI LINK”, the ventilator operation will be interlocked with the air conditioner operation. (downwards) ” (the most horizontal) VENTILATION OPERATION NOT LINKED WITH UNIT’S OPERATION the position of the louver 1 Press “ VENTI” button. ” is displayed, and the ventilation operation begins. ” (the most downwards) 9 Press SET button (Fixing of the lower limit position) Upper limit position and lower limit position are fixed, and the set positions are displayed for two seconds, then setting is completed.

After the setting is completed, the louver which was set moves from the original position to the lower limit position, and goes back to the original position again. (This operation is not performed if the indoor unit and/or indoor unit fan is in operation.) [Example] ” (lit for two seconds) И ” (return to the position of shipmen) Stop Press VENTI” button again. NOTICE [EXAMPLE] For Upper position 2, Lower position 6 If no ventilator is connected, no operation can be performed by pressing the ventilation button. (“ ” is displayed). Upper position 1 Press button. If a ventilator is connected, ventilation will operate automatically. ” is displayed.

VENTILATION OPERATION LINKED WITH UNIT’S OPERATION Movable range И 1 Note : If the upper limit position number and the lower limit position number are set to the same position, the louver is fixed at that position. And auto swing does not function. Lower position 10 Press button. Louver adjusting mode ends and returns to the original display. Stop Press button again. NOTICE No operation can be performed by pressing the ventilation button. ” is displayed). NOTICE If you press RESET button during settings, the display will return to previous display.

If you press button during settings, the mode will be ended and return to original display, and the settings that have not been completed will become invalid. When plural remote controllers are connected, louver position setting cannot be set by slave remote control. FOR COMFORTABLE USE Clean the filter frequently See page 16 The filter should be cleaned when the “Filter cleaning” message is displayed, and at the end of cooling and heating seasons. Block direct sunlight and prevent draft Block direct sunlight with blinds and curtains during cooling. Close the windows and doors except when ventilation is necessary.

It is possible to switch between the combination of upper and lower air outlets and upper air outlet. Not operable while the air conditioner is ON. When the upper airflow is selected, UPPER AIR FLOW LED on the unit display will light green only under run. 1. Stop the air conditioner. 2. Set the upper land lower limit position of the louver No.1 from the wired remote control. For the method of changing the setting, refer to HOW TO SET THE AIRFLOW DIRECTION on page 11. A In case of selecting to upper airflow. Set the upper and lower limit position to UPPER 2 and LOWER 2. (No.1 UPPER 2 / LOWER 2) B In case of selecting to upper and lower airflow.

Set the upper and lower limit position to UPPER 5 and LOWER 5. (No.1 UPPER 5 / LOWER 5) If the filter is clogged… The cooling/heating capacity will get reduced. Moreover it leads to waste of electricity and larger operation noise. It may cause failure. Dew may form and drop during cooling. Adjust the airflow properly Do not expose yourself directly to the airflow for too long time. For small animals and plants, it is harmful as well. If you feel cold underneath your feet during heating If the ceiling is so high that the warm airflow does not circulate underneath your feet, it is recommended to use a circulator. Consult your dealer for more detail.

Do not block the inlet and outlet grilles of the indoor and outdoor units. Excessive load to the unit may cause failure. Stop the operation and turn the power supply off if there are any possibility of lightning strikes during a thunderstorm. Lightning strikes may lead to the failure of air-conditioning system. Keep moderate room temperature Too much cooling or heating is not good for your health. It will also waste the electricity. 12 HOW TO SET THE AIRFLOW DIRECTION AIROUTLET SELECTION (IN CASE OF FDFW)