Victron Energy · MultiPlus 2kVA 230V · 26 pp.
Victron MultiPlus 2kVA 230V Inverter User & Service Manual PDF
Руководство пользователя для инвертора MultiPlus 2kVA 230V, включая инструкции по установке, эксплуатации и настройке.
Related manuals
Contents
Document text
Table of Contents
MultiPlus 2kVA 230V Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS ................................................... 1 2. Description ............................................................................................................................ 3 2.1. General ....................................................................................................................... 3 2.2. Battery charger .............................................................................................................. 3 2.3. Self consumption – solar energy storage systems ...................................................................... 4 3.
Operation .............................................................................................................................. 5 3.1. On / Off / Charger-only Switch ............................................................................................. 5 3.2. Remote control .............................................................................................................. 5 3.3. LED Indications .............................................................................................................. 5 4. Installation ............................................................................................................................. 7 4.1.
Location ...................................................................................................................... 7 4.2. Connection of the Battery cables .......................................................................................... 7 4.3. Connection of the AC cabling .............................................................................................. 8 4.4. Optional Connections ....................................................................................................... 8 4.4.1. Second Battery .................................................................................................... 8 4.4.2.
Temperature Sensor .............................................................................................. 8 4.4.3. Remote Control .................................................................................................... 8 4.4.4. Programmable relay .............................................................................................. 9 4.4.5. Parallel Connection (see appendix C) .......................................................................... 9 4.4.6. Three-phase operation (see appendix D) ...................................................................... 9 5.
Configuration ....................................................................................................................... 10 5.1. Standard settings: ready for use ......................................................................................... 10 5.2. Explanation of settings .................................................................................................... 10 5.3. Configuration of the MultiPlus ............................................................................................ 12 5.3.1. VE.Bus Quick Configure Setup ................................................................................ 13 5.3.2.
VE.Bus System Configurator .................................................................................. 13 5.4. Configuration with DIP switches ......................................................................................... 13 5.4.1. DIP switch 1 to 3 ................................................................................................ 13 5.4.2. Exemplary settings .............................................................................................. 13 6. Maintenance ......................................................................................................................... 15 7.
Trouble Shooting Table ........................................................................................................... 16 8. Technical Data ...................................................................................................................... 18 9. APPENDIX ........................................................................................................................... 20 9.1. Appendix A: overview connections ...................................................................................... 20 9.2. Appendix B: installation information ..................................................................................... 20 9.3. Appendix C:
parallel connection ......................................................................................... 22 9.4. Appendix D: three-phase connection ................................................................................... 22 9.5. Appendix E: charge algorithm ............................................................................................ 22 9.6. Appendix F: temperature compensation ................................................................................ 23 9.7. Appendix G: dimensions .................................................................................................. 24
1. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS
MultiPlus 2kVA 230V 1. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS General This manual contains important safety and operating instructions for marine unit MultiPlus. CAUTION – To reduce risk of injury, charge only VRLA or Li-Ion rechargeable batteries. Other types of batteries may burst causing personal injury and damage. Do not expose charger to rain or snow. Use of an attachment not recommended or sold by the marine unit manufacturer may result in a risk of fire, electric shock, or injury to persons. Do not disassemble marine unit; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
To reduce risk of electric shock, unplug marine unit from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. WARNING: RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF THE UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING THE UNIT IN THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY. To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any unit you intend to use in the vicinity of the battery.
Review cautionary marking on these products and on engine. PERSONAL PRECAUTIONS i. Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. ii. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. iii. Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery. iv. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 10 min and get medical attention immediately. v.
NEVER smoke or allow a spark or flame in the vicinity of the battery or engine. vi. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion. vii. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld a ring or the like to metal, causing a severe burn. viii. NEVER charge a frozen battery. ix. If necessary to remove battery from vessel, always remove grounded terminal from battery first.
Make sure all accessories in the vessels are off, so as not to cause an arc. x. Be sure area around battery is well ventilated. xi. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes. xii. Study all battery manufacturer’s specific precautions such as removing or not removing cell caps while charging and recommended rates of charge. xiii. Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without cell caps, carefully follow manufacturer’s recharging instructions. MARINE UNIT LOCATION i.
Locate marine unit away from battery in a separate, well ventilated compartment. ii. Never place marine unit directly above battery; gases from battery will corrode and damage marine unit. iii. Never allow battery acid to drip on marine unit when reading gravity or filling battery. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Page 1
1. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS
MultiPlus 2kVA 230V iv. Do not operate marine unit in a closed-in area or restrict ventilation in any way. DC CONNECTION PRECAUTIONS Connect and disconnect DC output connections only after setting any marine unit switches to off position and removing AC cord from electric outlet or opening AC disconnect. EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES COAST GUARD ELECTRICAL REGULATIONS (33CFR183, SUB PART I). GROUNDING INSTRUCTIONS This marine unit should be connected to a grounded, metal, permanent wiring system; or an equipment-grounding conductor should be run with circuit conductors and connected to equipment-grounding terminal or lead on unit.
Connections to unit should comply with all local codes and ordinances. Please familiarize yourself with the safety features and instructions by first reading the documentation supplied with this product before using the equipment. This product has been designed and tested in accordance with international standards. The equipment must be used exclusively for the purpose for which it was designed. ELECTRIC SHOCK HAZARD The product is used in conjunction with a permanent energy source (battery). Input and/or output terminals may still be dangerously energized, even when the equipment is switched off.
Always switch off the AC supply and the battery before carrying out maintenance or servicing the product. The product has no internal user-serviceable components. Do not remove the front plate or operate the product if any panels have been removed. All servicing must be undertaken by qualified personnel. Never use the product where there is a risk of gas or dust explosions. Consult the battery manufacturer's information to ascertain that the product is intended for use in conjunction with the battery. Always comply with the battery manufacturer's safety instructions. Never try to charge non-rechargeable - or frozen batteries. The converter/inverter is intended to recharge batteries.
The battery that is connected to this product is only suitable if it complies with the given battery standard for that battery type and is provided with a battery management system that will monitor and control the electrical and thermal health of the battery during charging. When installing this converter/inverter, the battery is to be verified as in compliance with the applicable battery standard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance Do not lift heavy loads without assistance. Installation Read the installation instructions in the installation manual before installing the equipment. This is a Safety Class I product (supplied with a protective grounding terminal). Uninterruptible protective grounding must be provided at the AC input and/or output terminals. Alternatively, the grounding point located externally on the product may be used. Whenever it is likely that the grounding protection has been damaged, the product must be turned off and secured against unintended operation; please contact qualified service staff.
Ensure that the equipment is used under the correct ambient conditions. Never operate the product in a wet or dusty environment. Ensure there is adequate free space for ventilation around the product and check that the ventilation vents are not blocked. Ensure that the DC and AC input cables are fused or fitted with circuit breakers. Ensure that the required system voltage does not exceed the product's capacity. Transport and Storage Ensure that the mains power and battery leads have been disconnected before storing or transporting the product. No liability can be accepted for any transport damage if the equipment is shipped in non-original packaging.
Store the product in a dry environment; the storage temperature must be between -40°C and 70°C. Consult the battery manufacturer's manual in respect of transport, storage, charging, recharging and disposal of the battery. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Page 2
2.2. Battery charger
MultiPlus 2kVA 230V 2. Description 2.1. General Multifunctional The MultiPlus gets its name from the multiple functions it can perform. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single enclosure. Beside these primary functions, however, the MultiPlus has several advanced features that provide a range of new applications as outlined below. Uninterrupted AC power In the event of a grid failure, or shore or generator power being disconnected, the inverter within the MultiPlus is automatically activated and takes over supply to the connected loads.
This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. Parallel and 3-phase operation capability Up to 6 inverters can operate in parallel to achieve higher power output. Operation in 3-phase configuration is also possible. PowerControl – Dealing with limited generator or shore side power With a Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus Compact to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, it is possible to reduce the size of generator needed or conversely enable more to be achieved from the typically limited shore connection. When the load reduces, the spare power is used to recharge the battery. Programmable relay The MultiPlus is equipped with a programmable relay that by default is set as an alarm relay.
The relay can be programmed for all kinds of other applications however, for example as a starter relay for a generator. 2.2. Battery charger Adaptive 4-stage charging characteristics: bulk – absorption – float – storage The microprocessor-driven adaptive battery management system can be adjusted for various types of batteries. The adaptive function automatically adapts the charging process to battery use. The right amount of charge: variable absorption time In the event of slight battery discharge, absorption is kept short to prevent overcharging and excessive gas formation. After deep discharging, the absorption time is automatically extended in order to fully charge the battery.
Preventing damage due to excessive gassing: the Battery Safe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, damage due to excessive gassing will be prevented by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the Storage mode float voltage is reduced to 2,2V/cell (13,2V for 12V battery) to minimise gassing and corrosion of the positive plates.
Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. Two DC outputs for charging two batteries The main DC terminal can supply the full output current. The second output, intended for charging a starter battery, is limited to 1A and has a slightly lower output voltage. Increasing service life of the battery: temperature compensation The temperature sensor (supplied with the product) serves to reduce charging voltage when battery temperature rises.
This is particularly important for maintenance-free batteries, which could otherwise dry out by overcharging. Page 3 Description