MultiPlus-II inverter/charger Australia 10. Technical specifications 10.1. Technical specifications Page 26 Technical specifications MultiPlus-II GX 230V 48/3000/35-32 48/5000/70-50 PowerControl & PowerAssist Yes Transfer switch 32A 50A Maximum AC input current 32A 50A INVERTER DC Input voltage range 38 – 66 V AC Output voltage 230 V ± 2% AC output frequency 50 Hz ± 0,1% (1) AC output current 11A 19A Cont. output power at 25°C (3) 3000 VA 5000 VA Cont. output power at 25°C 2400 W 4000 W Cont. output power at 40°C 2200 W 3700 W Cont.

output power at 65°C 1700 W 3000 W Max apparent feed-in power 3000 VA 5000 VA Peak power 5500 W 9000 W Maximum output fault current 32A for 1s 53A for 1s Maximum output overcurrent protection 32A 53A Active anti-islanding method Frequency Shift method Maximum battery discharge current 75A 110A Maximum efficiency 95% 96% Zero load power 11 W 18 W Zero load power in AES mode 7 W 12 W Zero load power in Search mode 2 W 2 W Inverter topology Isolated CHARGER AC Input voltage range GENERAL 187-250 V AC Input frequency range 45 – 65 Hz Charge voltage 'absorption' 57.6 V Charge voltage 'float' 55.2 V Storage mode 52.8 V Max. battery charge current (4) 35 A 70 A Battery temperature sensor Optional.

Order number: ASS000001000 Compatible battery chemistries Lead-acid, Lithium, Zinc-Bromine and others (5) GENERAL Auxiliary AC output Yes (32A) External AC current sensor (optional) 100A Programmable relay (6) Yes Protection (2) a - g Inbuilt GX device Yes