Victron Energy Nucleo GX — 12.1. Introduction and features

Nucleo GX Manual 12. DVCC - Distributed Voltage and Current Control 12.1. Introduction and features Enabling DVCC (under Settings → System Setup → Charge Control) changes the GX device from a passive monitor into an active system controller. The available DVCC features depend on: The type of battery in use The installed Victron components Their configuration Example 1 - Managed CAN-bus batteries: When a managed CAN-bus BMS battery is connected, the GX device receives:

Charge Voltage Limit (CVL) Charge Current Limit (CCL) Discharge Current Limit (DCL) These values are passed to connected inverter/chargers, solar chargers, and Orion XS DC-DC chargers, which then disable their own charging algorithms and follow the battery’s instructions directly. Example 2 - Lead-acid batteries: For lead-acid systems, DVCC enables: A configurable system-wide charge current limit, where the GX device actively limits the inverter/charger if solar chargers are already operating at full output. Shared Temperature Sense (STS) Shared Current Sense (SCS) These features enhance coordinated charging behaviour across the system.

This table shows the recommended settings for different battery types: DVCC - Distributed Voltage and Current Control Page 105 Lead-acid VE.Bus BMS V1 Lithium VE.Bus BMS V21) Lithium VE.Bus BMS NG1) Lithium Supported 3rd party managed batteries2) Auto-config No No No No 2) System charge current Yes Yes Yes Yes 2) Should you enable SVS? Yes 3), 4) 3), 4) 3), 4) 2) Should you enable STS? Yes No No No 2) Should you enable SCS Yes 3), 4) 3), 4) 3), 4) 2) 1) DVCC must be enabled for the GX device to control the solar chargers, Inverter RS or Multi RS in a system with a VE.Bus BMS V2 or VE.Bus BMS NG.

2) Use the Battery Compatibility manual to see which parameters need to be set and which are set automatically. 3) In an ESS system the VE.Bus device is already synced with the solar chargers, so we recommend leaving SVS and SCS off. 4) For all other systems: If a BMV or SmartShunt is installed, we recommend enabling SVS and SCS. In all other cases, leave SVS and SCS disabled. 5) Solar Chargers, Inverter/Chargers, Multi RS, Inverter RS and Orion XS do not require wiring. All other loads and chargers must be wired and controlled via ATC/ATD.