Victron Energy Nucleo GX — 12.5. DVCC features when using CAN-bus BMS battery

Nucleo GX Manual 12.4.6. Controlling BMS 12.5. DVCC features when using CAN-bus BMS battery This section applies to all systems using an intelligent battery BMS connected via CAN-bus.  This excludes the Victron VE.Bus BMS. When inverting (i.e., in island mode), Multis and Quattros will shut down if the maximum discharge current is set to zero. They will automatically restart when either AC mains is restored or the BMS increases the maximum discharge current. For more information on how the maximum charge current is configured, including prioritization of solar, refer to the previous section, Limit charge current [110] .

It is important to note that configuring charge voltages or charge profiles in VEConfigure or VictronConnect is unnecessary and has no effect. The Multis, Quattros, Multi and Inverter RS, MPPT Solar Chargers, and Orion XS DC-DC battery chargers will charge using the voltage received via CAN-bus from the battery. This setup also applies to systems with a Lynx Smart BMS or Lynx Smart BMS NG connected to a GX device. DVCC - Distributed Voltage and Current Control Page 112 For systems with multiple BMSs connected, this feature enables the selection of a specific BMS for DVCC.

It also allows a BMV or SmartShunt to be used for SoC tracking by configuring the BMV as the battery monitor (Settings → System setup → Batteries → Battery monitor), while the BMS remains active for DVCC. This setting is available in the Settings → System Setup → Charge Control menu on the GX device. Such intelligent BMS sends the following parameters to the GX device: 1. Charge voltage limit (CVL): the maximum charge voltage that the battery currently accepts. 2. Charge current limit (CCL): the maximum charge current requested by the battery. 3. Discharge current limit (DCL): the maximum discharge current as requested by the battery.

For all three parameters, some types of batteries transmit dynamic values. For example they determine the maximum charge voltage based on cell voltages, state of charge, or for example temperature. Other makes and brands use a fixed value. For such batteries there is no need to wire allow to charge (ATC) and allow to discharge (ATD) connections to the AUX inputs of a Multi or Quattro.