Victron Energy Nucleo GX — 12.4.5. Shared Current Sense (SCS)

Nucleo GX Manual Do not use this feature for other purposes. Improper use may prevent cell balancing from occurring, leading to severe long-term imbalance. If the voltage is set above the CVL (Charge Voltage Limit) from the battery BMS, the lower value will be applied. 12.4.3. Shared Voltage Sense (SVS) 12.4.4. Shared Temperature Sense (STS) 12.4.5. Shared Current Sense (SCS) DVCC - Distributed Voltage and Current Control Page 111 This feature is compatible with VE.Bus devices, VE.Direct and VE.Can MPPT solar chargers, Orion XS DC-DC battery chargers, as well as Inverter RS and Multi RS. The system automatically selects the optimal voltage measurement.

If available, it prioritises the voltage from the BMS or a BMV battery monitor. If neither is accessible, it defaults to the battery voltage reported by the VE.Bus system. The voltage displayed on the GUI corresponds to the selected voltage measurement. Shared Voltage Sense (SVS) is enabled by default when DVCC is active. It can be manually disabled via a switch in Settings → System Setup → Charge Control. However, SVS (and DVCC) is force-enabled for the Lynx Smart BMS and Lynx Smart BMS NG and cannot be modified. Note that SVS is force-disabled for some batteries. Please see the compatibility page for your battery.

STS allows the GX device to forward the measured battery temperature to all connected inverter/chargers, MPPT solar chargers, and Orion XS DC-DC chargers. You can select the temperature source from: • BMV-702 / BMV-712 • SmartShunt • Lynx Shunt VE.Can battery monitors • Temperature input on the GX device (if available) • Multi/Quattro inverter/charger • MPPT solar charger (with sensor installed) Note: STS is forced disabled for the Lynx Smart BMS, Lynx Smart BMS NG, and some managed batteries. Refer to the battery compatibility page for details.

This feature shares the battery current, as measured by a battery monitor connected to the GX device, with all MPPT solar chargers and Orion XS DC-DC battery chargers. These devices can use the shared current for the tail current mechanism, which ends absorption when the battery current drops below a set threshold. → Refer to the specific product documentation for configuration details. Applicable only to systems not using ESS and not using a managed battery, as charge control for MPPT solar chargers and Orion XS is external in those cases. Note: Requires MPPT solar charger firmware v1.47 or later.