Victron Energy Nucleo GX — GX device configuration

Nucleo GX Manual 14.5.3. Wiring The Furuno device needs to be connected to the GX device using Ethernet. Its not possible to connect over WiFi. For the Ethernet connection, a standard Ethernet cable can be used. The GX device can either be connected directly to the MFD or through a network router/switch. 14.5.4. Configuration Ethernet configuration It is possible to connect a router to the same LAN, allowing the GX device to connect to the internet. Ensure that the Gateway and DNS Server settings of the GX device are set to the router's IP address, and that the router’s LAN IP address is configured within the same subnet. It is not possible to use a GX GSM or a GX LTE 4G device.

GX device configuration Page 134 Marine MFD integration by App On the Victron GX device, ensure the Ethernet cable is connected, then go to Settings → Connectivity → Ethernet and configure the settings according to the table below: Setting Value IP configuration Manual IP address 172.31.201.12 Netmask 255.255.0.0 Gateway 0.0.0.0 or the IP address of the router in your network DNS Server 0.0.0.0 or the IP address of the router in your network 1. On the Victron GX device, go to Settings → Integrations, and there enable MQTT Access. 2. Next, go to Settings → System Setup → Batteries → Battery Measurements, and there set up what batteries you want to see on the MFD; and by what name. 3.

For boats, RVs and other applications with DC loads such as lighting and a Battery Monitor installed, make sure to enable the “Has DC system setting”. For more information about it, see the Menu structure and configurable parameters chapter.