Nucleo GX Manual 14.5.5. Configuring Multiple Tank Level Measurements (Furuno) Modern Furuno MFDs such as the NavNet TZtouch3 series are capable of displaying different types of tank levels. The following restrictions apply: 1. Currently, the NavNet TZtouch3 series can only display Fuel (default), Fresh Water and Black Water with up to 6 tanks for each of the three fluid types. However, it is possible to change the "Nickname" for each individual tank in the Engine & Tank Manual Setup menu. 2. All tank senders as mentioned in the chapter Connecting Victron products and Connecting supported non-Victron products are supported.
Configuration step-by-step Before proceeding with the following steps, you must connect the GX device to the NMEA 2000 network to which the MFD is connected. Use our VE.Can to NMEA 2000 micro-C male cable to connect the GX device to the NMEA 2000 network and ensure NMEA2000-out of the VE.Can port is enabled in the GX device. The procedure below does not replace the Furuno manual; Be sure to read the Furuno documentation that accompanies your MFD; There are some differences in the menu navigation of the various MFDs. 1. Connect the tank sensors to your GX device. 2. Make sure the tank sensors are set to a fluid type supported by your MFD.
This is done in the setup menu of the tank sensor in the Remote Console - Device List → [your_tank_sensor] → Setup → Fluid type 3. The Furuno MFD will automatically detect tanks connected to the same NMEA 2000 network. If this is not possible (check the Engine & Tank Automatic Setup menu), the tanks can be set manually using the Engine & Tank Manual Setup menu. 4. Set up an "Instrument Display" of your choice and add the respective tanks as an "Indication" (as outlined in the Operator's manual) to the instrument display. 14.5.6. NMEA 2000 Besides connecting over ethernet, a Furuno MFD can also be connected to the Victron system using NMEA 2000.
If you’re new to NMEA 2000 & Victron, start with reading the Marine MFD integration by NMEA 2000 chapter. This chapter documents the specifics when displaying Victron NMEA 2000 information on Furuno MFDs. Note that this is not meant to be an extensive guide. It's the simple result of our R&D checking everything on a Furuno MFD. The functionality is (mostly) dictated by Furuno software and may therefore also change and improve when Furuno company changes their software. The MFD can be configured easily to display the data from the GX device. To display tank data, there is no need to change any instance.
In order to properly display Battery/DC data from Victron equipment, you need to change the Data instances of the PGNs that are sent out. See here for how to do that: Changing NMEA 2000 Instances , section Data instances. To view NMEA 2000 devices on the MFD, go to Settings > Initial Setup > Data Aquisition > Sensor List. Here you can view basic information and change Device instances and custom names. 14.5.7. Generic and supported PGNs The following Victron related PGNs are supported: Page 135 Marine MFD integration by App