Victron Energy Nucleo GX — 18.1. Error Codes

Nucleo GX Manual 18. Troubleshooting 18.1. Error Codes Different origins of errors The GX device can display its own error codes, as well as those from connected devices.For device-specific codes, refer to: Multi and Quattro inverter/chargers: VE.Bus Error Codes MPPT Solar Chargers: MPPT Solar Charger Error Codes GX Error #42 - Storage corrupt The internal flash memory is corrupt. This partition stores settings, serial numbers, and Wi-Fi credentials. Solution: The device must be returned for repair or replacement. This cannot be fixed via firmware or in the field. GX Error #46 - Data partition full The alarm triggers when free space on the data partition drops below 10%.

A full data partition can cause Venus OS to malfunction and prevent services from starting. The most common cause is data written by third-party apps such as Node-RED or Signal K. To see which apps are installed, go to Settings → General → Support status. For solutions, see Venus OS Large - Disk space issues / data partition full GX Error #47 - Data partition issue The internal storage is likely damaged, causing the device to lose configuration. Solution: Contact your dealer or installer. See our Victron Energy Support page. GX Error #48 - DVCC with incompatible firmware DVCC is enabled, but not all system components are running compatible firmware. Solution:

Refer to the DVCC chapter of this manual for firmware requirements. Note for systems with Pylontech and BMZ batteries: Since Venus OS v2.80, DVCC is enforced for Pylontech and BMZ batteries. Older systems may show this error. Solution: Disable automatic updates; Settings → General → Firmware → Online updates → Auto update. Roll back to v2.73 (see Install a specific firmware version from SD/USB ). And after that, consider having an installer update all device firmware. Note for systems with BYD, MG Energy Systems and Victron Lynx Ion BMS batteries: Since Venus OS v2.40, DVCC auto-enables for supported BMS types. Older systems may lack components to support this. Solution:

Disable automatic updates; Settings → General → Firmware → Online updates → Auto update. Roll back to v2.33; to roll back to a previous firmware version see Install a specific firmware version from SD/USB . Ensure DVCC is disabled. Consult your installer to check if your system uses two-wire control (earlier alternative to DVCC). If there are no charge/discharge wires between BMS, inverter/chargers, and charge controllers, DVCC is required for the above-mentioned battery brands. This also requires minimum firmware versions on connected devices. GX Error #49 - Grid meter not found In ESS setups with External Grid Meter selected, no meter was detected. Solution:

Check system wiring and configuration. GX Error #51 - mk3 firmware needs update Update the MK3 controller inside the GX device to enable recent features like generator start/stop warm-up/cooldown. To update: Page 159 Troubleshooting