Victron Energy Nucleo GX — 18.2.15. Q15: What type of networking is used by the Nucleo GX (TCP and UDP ports)?

Nucleo GX Manual 18.2.10. Q10: I have multiple Solar chargers MPPT 150/70 running in parallel. From which one will I see the relay status in the NGX menu? From a random one. 18.2.11. Q11: How long should an automatic update take? The size of the download typically is around 90MB. After download it will install the files which can take up to 5 minutes. 18.2.12. Q12: I have a VGR with IO Extender, how can I replace this with a Nucleo GX? It is not yet possible to replace the IO Extender functionality. 18.2.13. Q13: Can I use Remote VEConfigure, as I was doing with the VGR2? Yes, see VE Power Setup manual 18.2.14. Q14:

The Blue Power Panel could be powered through the VE.Net network, can I also do that with a Nucleo GX? No, a Nucleo GX always needs to be powered itself. 18.2.15. Q15: What type of networking is used by the Nucleo GX (TCP and UDP ports)? Basics: The Nucleo GX needs to have a valid IP address including a working DNS server and gateway. By default obtained from a DHCP server. Manual configuration is also possible. DNS port 53 UDP and TCP NTP (time sync) UDP port 123. NTP uses a pool of servers provided by ntp.org , so this will connect to a wide variety of servers. VRM Portal:

Both in 'VRM read-only' mode and 'VRM full' mode, data is transmitted to the VRM Portal using ccgxlogging.victronenergy.com . This address resolves to multiple IP addresses, and posting is done via HTTPS POST and GET requests on port 443. There is an option in the menu to use HTTP instead, port 80. Note that in that case it will still send sensitive data such as related access keys (required for 'VRM full' mode) over HTTPS/443. Firmware updates: The NGX connects to https://updates.victronenergy.com/ on port 443. Remote support and Remote Console on VRM: An outbound reverse SSH connection is made to relaynearme46.victronenergy.com when either one, or both, of those features are enabled.

The supporthosts.victronenergy.com record resolves to multiple IP addresses, and the DNS uses Geo-Location to resolve it to the nearest server. This outbound SSH connection tries multiple ports: port 22, port 80 or port 443. The first that works is used, and in case it loses connection it will retry them all again. No port forwarding or other internet router configuration is necessary to use these features. More information about the Remote Support feature is in the next FAQ item. More information about troubleshooting Remote Console on VRM is in here: Remote Console on VRM - Troubleshooting .

Firewall / IP Address Filtering If installed in a network environment where strict outgoing IP address filtering is in place, the required addresses to approve can be obtained by resolving the A and AAAA records of the aforementioned DNS names. It depends on the firewall software used whether usage of DNS names in the rule set will resolve to one or multiple addresses, or whether it will continiously re-resolve to detect changes. It is likely neither of those are true, so custom monitoring or tooling is required. Also note that the DNS names used are subject to change in future Venus versions. Two-way communication (Remote VEConfig and Remote Firmware updates):

Connects to mqtt-rpc.victronenergy.com on port 443; and also connects to the mqtt{1 to 128}.victronenergy.com server farm. MQTT on LAN: When enabled, a local MQTT broker is started, which accepts TCP connections on port 8883 (SSL) and 1883 (Plain text). Page 162 Troubleshooting