Nucleo GX Manual Depending on, the NGX will also (try to) connect to the Victron MQTT cloud servers. This connection always uses SSL and port 8883. Remote Console on LAN: Remote Console on LAN requires port 80 (small website hosted the GX device). And also requires port 81, which is the listening port for the websocket tunnel to VNC. Modbus TCP: When enabled, the ModbusTCP server listens on the common designated port for Modbus TCP, which is 502. SSH Root Access: Port 22 - see the Venus OS root access documentation . This is a software developers feature. 18.2.16. Q16: What is the functionality behind the menu item Remote support in the General menu?
Enabling remote support grants Victron Engineers access the device for diagnostics and troubleshooting over the reverse SSH tunnel that is maintained when the GX's VRM mode is set to full. If the VRM mode is not set to full, the tunnel will be set up specifically for remote support. The connection uses ports 80, 22, or 443 to supporthosts.victronenergy.com and works behind most firewalls. Remote support is disabled by default. 18.2.17. Q17: I don’t see support for VE.Net products in the list, is that still coming? No. 18.2.18. Q18: What is the data usage of the Nucleo GX?
Data usage varies greatly depending on the number of connected products, system behaviour, logging interval, VRM access mode, and features like Remote Support or update checks. If you’re on a limited data plan, monitor usage during normal operation. Most routers offer built-in traffic counters; advanced tools like Wireshark provide detailed tracking. The current maximum is 9 sensors (since Nucleo GX v1.31). Note that each need to be configured separately with an assistant in the Multi or Quattro to which it is wired. 18.2.19. Q19: How many AC Current Sensors can I connect in one VE.Bus system? 18.2.20. Q20:
Issues with Multi not starting when NGX is connected / Caution when powering the NGX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro Ensure that both the GX device and the MultiPlus are running the latest firmware. If the GX device is powered via an AC adaptor connected to the AC-out of a VE.Bus Inverter, Multi or Quattro, a deadlock can occur after the VE.Bus device is powered down, for example, during a black start or fault. In this state, the VE.Bus product will not start until the GX device is powered, but the GX device cannot start without power either. How to resolve the deadlock Unplug the VE.Bus cable from the GX device briefly.
The VE.Bus device will immediately begin to boot. How to avoid the deadlock There are two options: Power the GX device directly from the battery Remove pin 7 in the VE.Bus cable connected to the GX device. Removing pin 7 allows the VE.Bus device to start independently of the GX device. The fastest and easiest way to remove this pin is with a very thin flat head screwdriver. This can be inserted into the pin grove, and then used to leverage out the gold contact plate. Be aware that this small highly conductive plate will fall out, so this should not be done over the open unit.
When using a Redflow ZBM2/ZCell battery, pin 7 should be removed even if the GX device is DC powered, to prevent deadlocks when the battery cluster reaches 0% SoC. Page 163 Troubleshooting