Victron Energy Nucleo GX — 20.1.2. RV-C out

Nucleo GX Manual 20. Appendix 20.1. RV-C 20.1.1. Introduction to RV-C The GX device offers integration with an RV-C network. The integration is split into two different types: 1. RV-C out: The GX device transmits data out to the RV-C network, where it can be read by connected displays and control centres. This includes data from Inverter/chargers, Battery chargers, Solar Chargers, batteries and more. 2. RV-C in: The GX device reads data from the RV-C network for displaying to the user (tank levels) as well as control (Lithionics batteries). Further details with regards to supported messages (DGNs) for both RV-C out as well as RV-C in, is provided in the following sections.

To enable RV-C, select the RV-C profile for one of the VE.Can ports in the Settings → Connectivity menu. A detailed specification of the protocol and message definition is publicly available on https://www.rv-c.com . 20.1.2. RV-C out Generic The GX main RV-C interface and all virtual devices report the minimum required DGNs: * In addition to DGN DM_RV 0x1FECA, also J1939 DGN DM01 0x0FECA is announced for all RV-C out devices to support older RV-C control panels that do not support the DM_RV DGN. Main interface The GX main interface identifies as “Control Panel” (DSA=68) on RV-C and is responsible for requesting and processing data from all RV-C nodes.

DC Source messages All DC connected devices are capable of reporting DC_SOURCE_STATUS_1. This includes the inverter/charger, inverter, charger, battery and solar charger services. VE.Bus Inverter/charger and Battery/BMS reports DC current and voltage, all other devices report voltage only. According to the RV-C spec, only one node is allowed to broadcast DC source messages from the same instance. Every device type has its own priority which is used to determine which node must send the DC source messages. Consider the following system:

Inverter/charger (DC source instance 1, prio 100) Solar charger (DC source instance 1, prio 90) AC charger with 3 outputs (DC source instance 1, 2 & 3, prio 80) Battery monitor (DC source instance 1, prio 119) In this case the battery monitor broadcasts DC source data with instance 1, as this has the highest priority. Additionally the AC charger broadcasts DC source data with instance 2 and 3 (output 2 and 3), as there are no other devices with those instances. More information about DC source messages in the RV-C specification manual . Chapter 6.5.1 explains the priority mechanism.

Page 168 Appendix DGN DGN# Description PRODUCT ID _ 0xFEEB Manufacturer, product name, serial number SOFTWARE ID _ 0xFEDA Software version DM RV _ 0x1FECA Diagnostics DM01* 0x0FECA Diagnostics