Nucleo GX Manual VE.Bus Inverter/charger Devices Only VE.Bus MultiPlus/Quattro. Phoenix Inverter VE.Bus is also exported by this service, but then with the number of AC inputs set to 0. The DSA is set to 66 (Inverter #1).
Instances Status Commands Page 169 Appendix Function Default Instance Configurable Range Inverter 1 1..13 Charger 1 1..13 Line #1 (L1) 0 0..1 Line #2 (L2) 1 0..1 DC Source 1 1..250 DGN DGN# Value INVERTER AC STATUS 1 _ _ _ 0x1FFD7 L1 AC out voltage, current, frequency L2 AC out voltage, current, frequency L2 data is not sent when not configured INVERTER AC STATUS 3 _ _ _ 0x1FFD5 L1 AC output power L2 AC output power L2 data is not sent when not configured INVERTER STATUS _ 0x1FFD4 Inverter status CHARGER AC STATUS 1 _ _ _ 0x1FFCA L1 AC input voltage, current, frequency L2 AC input voltage, current, frequency L2 data is not sent when not configured CHARGER AC STATUS 2 _ _ _ 0x1FFC9 Input current limit CHARGER AC STATUS 3C _ _ _ 0x1FFC8 L1 AC input power L2 AC input power L2 data is not sent when not configured Power is always positive, also in case of feed-in CHARGER STATUS _ 0x1FFC7 Charger state CHARGER STATUS 2 _ _ 0x1FEA3 DC voltage, current Charger priority aligns with DC source priority CHARGER CONFIGURATION STATUS _ _ 0x1FFC6 Maximum charge current CHARGER CONFIGURATION STATUS 2 _ _ _ 0x1FF96 Input current limit, Maximum charge current (%) DC SOURCE STATUS 1 _ _ _ 0x1FFFD DC voltage, current Fixed priority of 100 (inverter/charger) DC SOURCE STATUS 2 _ _ _ 0x1FFFC Battery temperature Fixed priority of 100 (inverter/charger) DGN DGN# Value INVERTER COMMAND 1) _ 0x1FFD3 Inverter enable/disable