Nucleo GX Manual 1) From RV-C you can control the charger and inverter part separately. These two on/off values are then combined into a single switch value (as seen on the VE.Bus page in the GX user interface, see top most item in below screenshot). If the inverter/charger is On, switching the charger off will result in Inverter only. Switching the inverter off will result in Charger only (when shore power is connected). Victron defines the following options to control a combined inverter/charger: This is reflected by the Switch menu option:
Page 170 Appendix DGN DGN# Value CHARGER COMMAND 1) _ 0x1FFC5 Charger enable/disable CHARGER CONFIGURATION COMMAND _ _ 0x1FFC4 Maximum charge current Note: this is a volatile setting and resets to the value the unit was configured with after a restart of the inverter/charger. CHARGER CONFIGURATION COMMAND 2 _ _ _ 0x1FF95 Charger input current limit State Remarks Off Both, inverter and charger are switched off Inverter only Only the inverter is switched on Charger only Only the charger is switched on On Both, inverter and charger are switched on