Nucleo GX Manual Battery/BMS Devices BMV, SmartShunt, Lynx Shunt, Lynx Ion, Lynx Smart BMS, BMS-Can batteries. The DSA is set to 69 (Battery State of Charge Monitor).
Instances Status Page 174 Appendix Function Default Instance Configurable Range Main 1 0..120 Starter 2 0..120 DGN DGN# Value DC SOURCE STATUS 1 _ _ _ 0x1FFFD Voltage, current Starter instance not sent if starter battery is not present DC SOURCE STATUS 2 _ _ _ 0x1FFFC Temperature, soc, time remaining DC SOURCE STATUS 4 _ _ _ 0x1FEC9 Desired maximum voltage, current, charge state Only sent for Lynx Smart BMS (NG) DC SOURCE STATUS 6 _ _ _ 0x1FEC7 HV limit/disconnect status, LV limit/disconnect status Only sent for Lynx Smart BMS (NG) and not adhering the 2s forewarning in case of a BMS disconnect DC SOURCE STATUS 11 _ _ _ 0x1FEA5 Discharge/charge on/off status, capacity, power Only sent for Lynx Smart BMS (NG) and not adhering the 2s forewarning in case of a BMS disconnect DC SOURCE LOAD CONTROL _ _ _ 0x1FDA8 Desired load state, minimum voltage, maximum current Only sent for Lynx Smart BMS (NG)