Nucleo GX Manual Tanks Devices Built-in tanks, GX tank, N2K tanks. The DSA is set to 73 (LPG) for LPG tanks and 72 (Water/Waste Tank System) for all other tank types. Instances Status Commands: RV-C supports only 4 tank types (0..3), while Victron supports up to 11 tank types. The table with the additional tank types is Victron specific and is compatible with the tank types we use. Supported tank types: Note that Vendor defined means that these types are not defined in RV-C, but only used for Victron RV-C devices. Alternator Devices Orion XS and compatible third party alternator controllers, such as the Wakespeed WS500. The DSA is set to 76 (Charge Controller).
Instances Page 175 Appendix Function Default Instance Configurable Range Tank 0 0..15 DGN DGN# Value TANK STATUS _ 0x1FFB7 Fluid type, relative level, absolute level, tank size Resolution fixed to 100 DGN DGN# Value TANK CALIBRATION COMMAND 0x1FFB6 Tank size Venus / NMEA 2000 RV-C Fluid type Fluid code Type Fuel 0 4 (Vendor defined) Fresh water 1 0 Waste (Grey) water 2 2 Livewell 3 5 (Vendor defined) Oil 4 6 (Vendor defined) Black water 5 1 Gasoline 6 7 (Vendor defined) Diesel 7 8 (Vendor defined) LPG 8 3 LNG 9 9 (Vendor defined) Hydraulic oil 10 10 (Vendor defined) Raw water 11 11 (Vendor defined) Function Default Instance Configurable Range Charger 3 1..13 DC Source 1 1..250