Nucleo GX Manual Status Commands Generator auto start/stop Devices Up to two GX generator auto start/stop instances can be expected, each with their own SA. One for the GX relay controlled instance and one for a connected genset, such as a Hatz.The DSA is set to 65 (Genstart Controller). Instances N/A Status Commands Since these command DGNs are lacking instancing, all GX generator auto start/stop instances are affected.
Page 176 Appendix DGN DGN# Value CHARGER STATUS _ 0x1FFC7 Charger state, goal voltage (if available), goal current (if available), percentage (if available) CHARGER STATUS 2 _ _ 0x1FEA3 Voltage, current Charger priority aligns with DC source priority CHARGER CONFIGURATION STATUS _ _ 0x1FFC6 Battery sensor, max charging current DC SOURCE STATUS 1 _ _ _ 0x1FFFD DC voltage Fixed priority of 70 DGN DGN# Value CHARGER COMMAND _ 0x1FFC5 Charger enable/disable DGN DGN# Value AGS DEMAND CONFIGURATION STATUS _ _ _ 0x1FED5 Disable on OEM Switch DGN DGN# Value AGS DEMAND CONFIGURATION COMMA _ _ _ ND 0x1FED4 Disable on OEM Switch GENERATOR DEMAND CONFIGURATION _ _ _ COMMAND 0x1FEE6 Disable on OEM Switch