Nucleo GX Manual If you need to connect more VE.Direct devices than there are VE.Direct ports, the following options are available: Use the VE.Direct to USB interface . Use a USB hub if more ports are required. Please refer to the Overview of connections [4] section for details on the maximum number of VE.Direct devices that can be connected. Notes on older VE.Direct MPPTs Some older models, like the MPPT 70/15, are not compatible with GX devices unless they meet a minimum hardware revision: The device must be from year/week 1308 or later. Firmware updates will not resolve incompatibility with earlier models. To identify your model: Check the serial number printed on the rear label. Example:
HQ 1309 DER4F means 2013, week 09, which is compatible. You can use a SmartShunt or BMV-712 to monitor individual DC circuits rather than the entire battery system. To do this, change the Monitor mode setting from Battery Monitor to DC Energy Meter using VictronConnect. 5.2.1. DC load monitor mode Available DC meter types Once DC Energy Meter mode is selected, the following types can be assigned in VictronConnect: Sources: Solar charger, Wind charger, Shaft generator, Alternator, Fuel cell, Water generator, DC-DC charger, AC charger, Generic source Loads:
Generic load, Electric drive, Fridge, Water pump, Bilge pump, DC system, Inverter, Water heater Integration with GX devices When connected to the Nucleo GX, the selected meter type along with current (A) and power (W) is displayed in the user interface and sent to the VRM Portal for remote monitoring. Special case: Type "DC System" 1. The DC System power display aggregates readings from all SmartShunts configured with the DC System type. This supports multi-location systems, for example, DC systems in both hulls of a catamaran. When configured as type “DC System”, the NGX offers extended functionality beyond data logging: 2. DVCC Charge Current Limiting is dynamically adjusted:
The GX device compensates for DC loads when setting charge current limits for Multis, Quattros, and Solar Chargers. For example: If a DC load of 50 A is being measured And the battery reports a CCL (Charge Current Limit) of 25 A Then the system sets a limit of 75 A to the charging sources → Resulting in optimised charging behaviour for Yachts, RVs, Coaches, and other systems with significant DC loads. Notes and limitations: This feature is supported only by SmartShunt and BMV-712. It is not available on BMV-700 or BMV-702. The Monitor mode must be configured using VictronConnect directly on the SmartShunt or BMV-712.
For setup instructions, refer to the BMV-712 or SmartShunt product manual on the Battery Monitor product page The NMEA2000-out feature does not support the DC meter types. For example, if a SmartShunt is configured to monitor an alternator, that data will not be available via NMEA 2000. Page 25 Connecting Victron products